ECD Simulation Inputs

  • Doolittle
  • 9.625" casing set at 7291ft
  • Simulation inputs from previous page:
    Plan 1 - TD 8100ft
    Run #1, Bit @ 8071ft
            Bit Nozzles: 10,10,10,10,10,10,10,10, TFA: 0.614in2
            Hole Size: 8.75 inches

  • Test
    Report Date
    Mud Density, ppg
    Viscometer Readings
    1
    Oct. 21, 2021
    9.15
    65.0/36.0/26.0/16.0/4.0/3.0

    Select the report date to use the relevant data for simulation
    Provide flow rate, gpm. Typical: 200-400 for 6.75" hole. 400-700 for 8.5" hole. 700-1200 for larger.